Note that these stars are in the starlist file "/kroot/starlists/000_elias.stds".
| Star | RA (1950) | Dec (1950) | Guide Star | J | H | K | L | J-K | H-K | K-L |
| HD 225023 | 00h 00m 11.8s | +35° 32' 14" | 41° | 7.065 | 6.985 | 6.960 | 0.105 | 0.025 | ||
| G158-27 | 00h 04m 12.0s | -07° 47'54" | 171° | 8.305 | 7.755 | 7.430 | 0.875 | 0.325 | ||
| HD 1160 | 00h 13m 23.1s | +03° 58' 24" | 115°, 239° | 7.055 | 7.045 | 7.040 | 7.025 | 0.015 | 0.005 | 0.015 |
| HD 2811 | 00h 28m 53.0s | -43° 52'58" | 104° | 7.170 | 7.090 | 7.065 | 7.040 | 0.105 | 0.025 | 0.025 |
| HD 3029 | 00h 31m 02.3s | +20° 09' 30" | 173°, 352° | 7.250 | 7.120 | 7.090 | 0.160 | 0.030 | ||
| Gl 105.5 | 02h 38m 07.6s | +00° 58' 57" | 188° | 7.240 | 6.635 | 6.525 | 6.460 | 0.715 | 0.110 | 0.065 |
| HD 18881 | 03h 00m 20.5s | +38° 12' 53" | 179°, 351° | 7.125 | 7.130 | 7.140 | -0.015 | -0.010 | ||
| HD 19904 | 03h 08m 49.1s | -39° 14'24" | 189°, 92° | 6.720 | 6.660 | 6.640 | 6.620 | 0.080 | 0.020 | 0.020 |
| G77-31 | 03h 10m 40.5s | +04° 35' 12" | 13°, 115° | 8.740 | 8.160 | 7.840 | 7.550 | 0.900 | 0.320 | 0.290 |
| HD 22686 | 03h 36m 18.8s | +02° 36' 05" | 93°, 348° | 7.195 | 7.190 | 7.185 | 7.195 | 0.010 | 0.005 | -0.010 |
| HD 38921 | 05h 45m 41.0s | -38° 14'51" | 20°, 123° | 7.570 | 7.550 | 7.535 | 7.525 | 0.035 | 0.015 | 0.010 |
| HD 40335 | 05h 55m 37.6s | +01° 51' 09" | 1°, 312° | 6.540 | 6.470 | 6.450 | 6.415 | 0.090 | 0.020 | 0.035 |
| HD 44612 | 06h 21m 09.7s | +43° 34' 35" | any, 2° | 7.060 | 7.035 | 7.040 | 0.020 | -0.005 | ||
| BD+0° 1694 | 06h 52m 07.3s | +00° 00' 52" | any, 62° | 5.640 | 4.810 | 4.585 | 4.415 | 1.055 | 0.225 | 0.170 |
| Gl 299 | 08h 09m 11.0s | +08° 59' 42" | 159° | 8.380 | 7.915 | 7.640 | 7.360 | 0.740 | 0.275 | 0.280 |
| HD 75223 | 08h 45m 29.8s | -39° 36'54" | 119° | 7.325 | 7.295 | 7.280 | 7.260 | 0.045 | 0.015 | 0.020 |
| HD 77281 | 08h 59m 05.4s | -01° 16'45" | 138° | 7.105 | 7.050 | 7.030 | 6.995 | 0.075 | 0.020 | 0.035 |
| Gl 347a | 09h 26m 25.0s | -07° 08'30" | 274° | 8.410 | 7.860 | 7.630 | 7.425 | 0.780 | 0.230 | 0.205 |
| HD 84800 | 09h 45m 35.9s | +43° 53' 56" | 232° | 7.560 | 7.530 | 7.530 | 0.030 | 0.000 | ||
| Gl 390 | 10h 22m 44.0s | -09° 58'36" | 346°, 264° | 6.870 | 6.250 | 6.045 | 5.880 | 0.825 | 0.205 | 0.165 |
| Gl 406 | 10h 54m 06.0s | +07° 19' 12" | 238° | 7.060 | 6.440 | 6.080 | 5.730 | 0.980 | 0.360 | 0.350 |
| HD 101452 | 11h 37m 45.1s | -38° 52'09" | 358° | 7.005 | 6.885 | 6.845 | 6.810 | 0.160 | 0.040 | 0.035 |
| HD 105601 | 12h 06m 56.1s | +38° 54' 39" | 88° | 6.810 | 6.715 | 6.685 | 0.125 | 0.030 | ||
| HD 106965 | 12h 15m 24.0s | +01° 51' 10" | 312° | 7.375 | 7.335 | 7.315 | 7.295 | 0.060 | 0.020 | 0.020 |
| HD 129653 | 14h 40m 38.2s | +36° 58' 07" | 129° | 6.980 | 6.940 | 6.920 | 0.060 | 0.020 | ||
| HD 129655 | 14h 41m 11.0s | -02° 17'38" | 109° | 6.815 | 6.720 | 6.690 | 6.665 | 0.125 | 0.030 | 0.025 |
| HD 130115 | 14h 44m 36.2s | -39° 43'04" | 152° | 6.855 | 6.845 | 6.835 | 6.810 | 0.020 | 0.010 | 0.025 |
| BD+3° 2954 | 14h 52m 23.2s | +03° 11' 33" | 242° | 5.840 | 4.995 | 4.805 | 4.650 | 1.035 | 0.190 | 0.155 |
| HD 136754 | 15h 19m 24.3s | +24° 31' 19" | 35° | 7.150 | 7.130 | 7.135 | 0.015 | -0.005 | ||
| BD+2° 2957 | 15h 22m 29.0s | +01° 41' 06" | 332°, 210° | 5.200 | 4.425 | 4.245 | 4.095 | 0.955 | 0.180 | 0.150 |
| S-R 3 | 16h 23m 07.7s | -24° 27'26" | 141° (ft.) | 7.705 | 6.965 | 6.520 | 1.185 | 0.445 | ||
| Oph S1 | 16h 23m 32.8s | -24° 16'44" | 308° | 8.800 | 7.270 | 6.330 | 5.770 | 2.470 | 0.940 | 0.560 |
| HD 161743 | 17h 45m 31.8s | -38° 06'11" | 125° | 7.620 | 7.620 | 7.615 | 7.605 | 0.005 | 0.005 | 0.010 |
| HD 161903 | 17h 45m 43.3s | -01° 47'34" | 102° | 7.170 | 7.055 | 7.020 | 6.985 | 0.150 | 0.035 | 0.035 |
| HD 162208 | 17h 46m 20.7s | +39° 59' 40" | 254° | 7.215 | 7.145 | 7.110 | 0.105 | 0.035 | ||
| Gl 748 | 19h 09m 38.0s | +02° 48' 36" | any, 271° | 7.075 | 6.545 | 6.305 | 0.770 | 0.240 | ||
| Gl 811.1 | 20h 54m 03.9s | -10° 38'23" | 53° | 7.755 | 7.150 | 6.930 | 6.740 | 0.825 | 0.220 | 0.190 |
| HD 201941 | 21h 10m 13.6s | +02° 26' 12" | 26° | 6.700 | 6.640 | 6.625 | 6.610 | 0.075 | 0.015 | 0.015 |
| HD 203856 | 21h 21m 37.1s | +39° 48' 12" | 101° | 6.925 | 6.880 | 6.860 | 0.065 | 0.020 | ||
| HD 205772 | 21h 35m 33.6s | -41° 16'26" | 115° | 7.765 | 7.685 | 7.655 | 7.635 | 0.110 | 0.030 | 0.020 |